2020e & 2020i Portable Turbidity MetersThe newly redesigned 2020 combines an advanced microprocessor with a patent-pending optical chamber resulting in higher accuracy and a wider range. |
|
![]() |
The multi-detector optical configuration assures long term stability and minimizes stray light and color interferences. All readings are determined by the process of signal averaging over a 5 second period. This minimizes fluctuations in readings attributed to large particles and results in rapid, highly repeatable measurements. Ideally suited for both low-level drinking water applications as well as monitoring high turbidity in the field. |
|
|
|
|
2020e version meets USEPA design criteria as specified by USEPA method 180.1. 2020i version meets design criteria for quantitative methods of turbidity using optical turbidimeters as specified by ISO 7027. Kits are supplied with 0, 1, and 10 NTU standard, sample bottle, four sample tubes, and an extra battery. AC power adapter is optional. |
Turbidity Specifications: |
|
|
Unit of Measure: |
NTU, FNU, FAU, ASBC, EBC |
|
Range: |
0-4000 |
|
Resolution: |
0.01 NTU/FNU 0.00-10.99, 0.1 NTU/FNU 11.00-109.9, |
|
Accuracy: |
±2% 0-100 NTU, ±3% above 100 NTU |
|
Detection Limit: |
0.05 NTU/FNU |
|
Range Selection: |
Automatic |
|
Reproducibility: |
0.02 NTU/FNU, 0.5 FAU |
|
Light Source: |
860nm LED (2020i ISO) |
Meter Features: |
|
|
Signal Averaging: |
Disabled, 2, 5, 10 |
|
Battery: |
9V |
|
AC Power: |
Optional |
|
Data Logging: |
4000 points |
|
Auto Shut-Off: |
Disabled, 5, 10, 30 |
|
Optional Software: |
SmartLink 2 |
|
Languages: |
English, French, Spanish, Japanese, Italian, Portuguese |
|
Response Time: |
<5 Seconds |
Item Description |
Order Code |
|
Model 2020e Kit |
1979-EPA |
|
Model 2020i Kit |
1979-ISO |
|
0 NTU Standard (ISO and EPA), 60 mL |
1480 |
|
1 NTU Standard (ISO), 60 mL |
1481 |
|
10 NTU Standard (ISO), 60 mL |
1482 |
|
100 NTU Standard (ISO), 60 mL |
1483 |
| 1 NTU Standard (EPA), 60 mL | 1484 |
| 10 NTU Standard (EPA), 60 mL | 1485 |
| 100 NTU Standard (EPA), 60 mL | 1486 |
| Formazin Standard Solution, 4000 NTU, 60 mL | 6195-H |
| AC Power Adapter (variable 100-240 V AC) | 1754 |
| Vial Ring (2-pk) | 0641 |
| Six-pack of vials | 0475 |
| RS232 Cable | 1772 |
| 2020e&i Meter Manual FREE in downloadable PDF format (Just Click Here) | 1979-MN.PDF |
| 2020e&i Meter CE Compliance Certifate in downloadable PDF format | 2020 CE Certificate |
| AMCO Turbidity Standards, ISO 7027 Certificate of Compliance | ISO7027.PDF |
LaMotte CompanyP.O. Box 329 | 802 Washington Avenue | Chestertown | Maryland | 21620 |