Chlorine (Individual Test Kits) |
||||
|
Chlorine: Free, combined, and total chlorine may be determined using DPD with either colorimetric or titrimetric methods. These determinations are generally limited to concentrations of 010 ppm, although the FAS titration can test higher concentrations with the addition of more DPD indicator. Higher concentrations require the iodometric titration, whereby the sample is acidified and iodide is added, which is oxidized by chlorine to iodine and is titrated with a standard thiosulfate solution. |
||||
Order Code/Model |
Test System |
Range/Sensitivity |
# of Tests
|
Shipping Code (Weight/lbs) |
|
3308* |
DPD Tablet Octa-Slide |
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl |
50 (2) |
NH (1) |
|
3312* |
DPD Tablet Octa-Slide |
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cl | 50 (2) | NH (1) |
|
3313* |
DPD Tablet Octa-Slide |
1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0 ppm Cl | 50 (2) | NH (1) |
|
3314* |
DPD Tablet 2 Octa-Slides |
Low: 0.11.0 ppm Cl High: 1.06.0 ppm Cl |
100 (2) | NH (1) |
|
3328 |
DPD Octa-Slide |
1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm Cl | 50 (2) | NH (1) |
|
3670-01 |
DPD Tablet Colorimeter |
04.0 ppm/0.05 ppm Cl | 100 (2) |
NH (4) |
|
3670-01-LI |
DPD Liquid Colorimeter |
0-4.0 ppm/0.05 ppm Cl | 144 (3) | N (5) |
DPD-FAS Titration |
||||
Order Code/Model |
Test System |
Range/Sensitivity |
# of Tests
|
Shipping Code (Weight/lbs) |
|
6806**† |
Oxidizer** Automatic Buret |
1 mL=0.1 mg Cl |
50 at 10 ppm (11) |
B (13+5) |
|
3176-01*† |
Direct Reading Titrator | 0-10 ppm/0.2 ppm Cl | 50 at 10 ppm (4) | HA (2) |
| 3624 DT |
Chlorine or Bromine Direct Reading Titrator |
0-10 ppm/0.2 ppm Cl or Br | 50 at 10 ppm (3) | NH (1) |
| 7514 CC-25 FAS |
Dropper Bottle Titration | 1 drop = 0.2 or 0.5 ppm Cl | 50 (2) |
NH (1) |
DPD Free Chlorine, Monochloramine, Dichloramine, & Total Chlorine |
||||
Order Code/Model |
Test System |
Range/Sensitivity |
# of Tests
|
Shipping Code (Weight/lbs) |
|
3316 |
DPD Tablet Octa-Slide |
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl |
50 (4) |
NH (1) |
DPD Free, Mono & Dichloramines, Total Chlorine, pH |
||||
Order Code/Model |
Test System |
Range/Sensitivity |
# of Tests
|
Shipping Code (Weight/lbs) |
|
6980 |
DPD Tablet/ Phenol Red Tablet 3 Octet Comparators |
Low: 0.11.0 ppm Cl High: 1.06.0 ppm Cl pH: 6.88.2 |
200 (5) |
NH (7) |
Iodometric Titration (For higher total chlorine levels) |
||||
Order Code/Model |
Test System |
Range/Sensitivity |
# of Tests
|
Shipping Code (Weight/lbs) |
|
4497-DR |
Direct Reading Titrator | 0200 ppm/4 ppm Cl |
50 at 200 ppm (3) |
HA (1) |
| 4497 PCT-DC |
Dropper Pipet | 1 drop = 10 ppm Cl | 50 at 200 ppm (3) | HA (1) |
| 4501 | Dropper Pipet | 1 drop = 1 ppm Cl | 50 (3) | NH (1) |
Chlorine Bleach, Iodometric Titration |
||||
Order Code/Model |
Test System |
Range/Sensitivity |
# of Tests
|
Shipping Code (Weight/lbs) |
|
7105-02 |
Direct Reading Titrator | 010%/0.2% Cl |
50 at 10% (3) |
HA (2) |
| 7894 LB |
Dropper Pipet | 1 drop = 0.005%, 0.05%, or 0.5% Cl | 50 at 0.1, 1.0, or 10% (3) | N (1) |
*(NPDWR) EPA Accepted
?(NPDES) EPA Accepted
Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.