Since 1919
LaMotte Smart2 Colorimeter
It all begins here...
What are you testing today?

Individual Test Kits:

Chlorine (Individual Test Kits)

Chlorine: Free, combined, and total chlorine may be determined using DPD with either colorimetric or titrimetric methods. These determinations are generally limited to concentrations of 0–10 ppm, although the FAS titration can test higher concentrations with the addition of more DPD indicator. Higher concentrations require the iodometric titration, whereby the sample is acidified and iodide is added, which is oxidized by chlorine to iodine and is titrated with a standard thiosulfate solution.

Order Code/Model
Test System
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code (Weight/lbs)

3308*
SL-26

DPD Tablet
Octa-Slide
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl

50 (2)

NH (1)

3312*
SL-MW

DPD Tablet
Octa-Slide
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cl 50 (2) NH (1)

3313*
SL-SWS

DPD Tablet
Octa-Slide
1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0 ppm Cl 50 (2) NH (1)

3314*
SL-16

DPD Tablet
2 Octa-Slides
Low: 0.1–1.0 ppm Cl
High: 1.0–6.0 ppm Cl
100 (2) NH (1)

3328
SL-60

DPD
Octa-Slide
1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm Cl 50 (2) NH (1)

3670-01
DC1200-CL

DPD Tablet
Colorimeter
0–4.0 ppm/0.05 ppm Cl 100 (2)

NH (4)

3670-01-LI
DC1200-CL-LI

DPD Liquid
Colorimeter
0-4.0 ppm/0.05 ppm Cl 144 (3) N (5)
DPD-FAS Titration
Order Code/Model
Test System
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code (Weight/lbs)

6806**†
DT

Oxidizer**
Automatic Buret
1 mL=0.1 mg Cl

50 at 10 ppm (11)

B (13+5)

3176-01*†
DT-DR

Direct Reading Titrator 0-10 ppm/0.2 ppm Cl 50 at 10 ppm (4) HA (2)
3624
DT
Chlorine or Bromine
Direct Reading Titrator
0-10 ppm/0.2 ppm Cl or Br 50 at 10 ppm (3) NH (1)
7514
CC-25 FAS
Dropper Bottle Titration 1 drop = 0.2 or 0.5 ppm Cl 50 (2)

NH (1)

DPD Free Chlorine, Monochloramine, Dichloramine, & Total Chlorine
Order Code/Model
Test System
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code (Weight/lbs)

3316
SL-1

DPD Tablet
Octa-Slide
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl

50 (4)

NH (1)

DPD Free, Mono & Dichloramines, Total Chlorine, pH
Order Code/Model
Test System
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code (Weight/lbs)

6980
LP-8

DPD Tablet/
Phenol Red Tablet
3 Octet Comparators
Low: 0.1–1.0 ppm Cl
High: 1.0–6.0 ppm Cl
pH: 6.8–8.2

200 (5)

NH (7)

Iodometric Titration (For higher total chlorine levels)
Order Code/Model
Test System
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code (Weight/lbs)

4497-DR
PCT-DR

Direct Reading Titrator 0–200 ppm/4 ppm Cl

50 at 200 ppm (3)

HA (1)

4497
PCT-DC
Dropper Pipet 1 drop = 10 ppm Cl 50 at 200 ppm (3) HA (1)
4501 Dropper Pipet 1 drop = 1 ppm Cl 50 (3) NH (1)
Chlorine Bleach, Iodometric Titration
Order Code/Model
Test System
Range/Sensitivity
# of Tests
(# Reagents)
Shipping Code (Weight/lbs)

7105-02

Direct Reading Titrator 0–10%/0.2% Cl

50 at 10% (3)

HA (2)

7894
LB
Dropper Pipet 1 drop = 0.005%, 0.05%, or 0.5% Cl 50 at 0.1, 1.0, or 10% (3) N (1)
Shipping Codes:

*(NPDWR) EPA Accepted
?(NPDES) EPA Accepted

Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.


LaMotte Company

P.O. Box 329 | 802 Washington Avenue | Chestertown | Maryland | 21620
Tel: 800-344-3100 (within the U.S.A.) | 410-778-3100 | 410-778-3101
Fax: 410-778-6394