Wastewater Lab |
|
|
| This self-contained laboratory includes a one liter plastic Imhoff Cone with support stand and polycarbonate settleometer for measuring settleability. Critical pH measurements are performed with the pH 5, digital pH meter. A maintenance free, gel-filled combination electrode, and three pH buffers (4.00, 7.00, 10.00) are provided. The Wastewater Lab also includes the Dissolved Oxygen (Code 7414) and Chlorine (Code 3176) test kits. |
Factor |
Method |
Range (# Tests) |
|
Free & Total Chlorine |
DPD-FAS |
010 ppm (50) |
| Dissolved Oxygen | Winkler | 010 ppm (50) |
| Settleable Solids | Gravimetric | 01000 mL/L(Unlimited) |
| Settleability | Gravimetric | 0100% (Unlimited) |
| Temperature | | 5° to 50°C (Unlimited) |
Meters |
Range |
|
pH 5 meter |
014 pH |
Item Description |
Shipping Code |
Order Code |
|
Model SW-04 |
HA |
7946-04 |
| Model SW-04 Reagent Refill | HA | R-7946-04 |
Storm Drain Monitoring Kit |
|
|
|
The Model SSDK Detection Kit was specifically designed and manufactured to meet US EPA requirements for field test procedures approved in the November 16, 1990 Federal Register to monitor illicit storm drain connections. Each unit includes tests for pH, Total Chlorine, Total Copper, Phenols, Detergent surfactants, Color and Turbidity. |
| The Model SSDK is packaged in a rugged portable carrying case for on-site use. Reagents are provided for 100 tests of each parameter (30 tests for Detergent). | |
Factor |
Method |
Range (# Tests) |
|
Phenols |
4-Aminoantipyrine Slide |
0-5.0 ppm |
| Copper |
Thiocarbamate Slide |
0-4.0 ppm |
| Detergents | Titration | 0.1 ppm sensitivity |
| Chlorine | DPD Slide | 0.2-3.0 ppm |
| Turbidity | Formazin Equivalent | L-M-H |
Meters |
Range |
|
Waterproof pH 1 PockeTester |
014 pH, 0.2 pH |
Item Description |
Shipping Code |
Order Code |
|
Model SSDK |
B |
7446 |
| Model SSDK Reagent Refill | B | R-7446-01 |
Corrosion Control Kit |
|
|
By determining corrosive conditions in water supplies, this test kit supports a water supplier’s lead in drinking water abatement program. Each unit includes tests for P and T alkalinity, calcium hardness, temperature, pH, phosphates, and total dissolved solids. Calculate saturation index by the Langelier method to indicate the corrosive conditions in water supplies. The Model CCK Corrosion Control kit is packaged in a portable carrying case for on-site use. |
![]() |
Factor |
Method |
Range (# Tests) |
|
Calcium Hardness |
Complexometric |
0200 ppm (50) |
| P & T Alkalinity | Neutralization | 0200 ppm (50) |
| Orthophosphate | Ascorbic Acid | 0.510 ppm (50) |
| Temperature | | 5° to +45°C (Unlimited) |
| Corrosion Index | | By calculation via chart (50) |
Meters |
Range |
|
Waterproof pH 1 PockeTester |
014 pH |
| Waterproof TDS 1 PockeTester | 101990 ppm |
Item Description |
Shipping Code |
Order Code |
|
Model CCK |
HA |
7436-01 |
| Model CCK Reagent Refill | HA |
R-7436-01 |
LaMotte CompanyP.O. Box 329 | 802 Washington Avenue | Chestertown | Maryland | 21620 |